2024-10-22
1. Insulation Failure: The insulation material of the transformer can degrade over time due to the high voltage levels. The insulation failure can cause the transformer to short-circuit or malfunction.
2. Overheating: The transformer can overheat if it is overloaded or if there is a fault in the system. Overheating can cause insulation failure and damage the transformer.
3. Moisture Ingress: Moisture can ingress into the transformer, which can cause the insulation to degrade and lead to a short-circuit. The moisture can also cause corrosion of the transformer windings.
4. Oil Leakage: The transformer oil can leak due to aging or damage to the transformer tank. The oil leakage can cause a fire and damage the transformer.
5. High Impedance: The high impedance of the transformer can lead to voltage drops and affect the efficiency of the system.
10kv voltage transformer is an essential component of the electrical transmission and distribution system. However, it is prone to various problems, including insulation failure, overheating, moisture ingress, oil leakage, and high impedance. It is critical to monitor and maintain the transformer regularly to avoid any catastrophic failure.
Zhejiang Dahu Electric Co.,Ltd. is a leading manufacturer of 10kv voltage transformers. The company has been in the industry for over 20 years and has a proven track record of providing high-quality electrical equipment. Zhejiang Dahu Electric Co.,Ltd. has a team of experienced professionals who can provide customized solutions to meet the specific needs of customers. You can reach out to the company at River@dahuelec.com for any inquiries or orders.
Bhuiyan M, Ullah ANM. (2013). Modeling and Analysis of 10kV Distribution Transformer for Overvoltage Protection. International Journal of Electrical and Computer Engineering (IJECE).
Shahid M, Khan AK, Hashmi MSJ. (2020). Condition monitoring of transformers: A review. Journal of Electrical Systems and Information Technology.
Tan H, Yang L, Li K, Luo N, Yang J, Lei Y. (2018). A Novel Monitoring System for Indoor 10 kV High Voltage Electromagnetic Voltage Transformers Based on an Optical Fiber Temperature Sensor. Sensors (Basel).
Lee SH, Lee JH, Won B. (2017). Method for Improving the Measurement Accuracy and Sensitivity of the Rogowski Coil for the 10 kV Voltage Transformer. Sensors (Basel).
Zhang H, Liu X. (2011). Numerical Analysis of Transient Electromagnetic Field of 10 kV Current Transformer. Procedia Engineering.
Mohiddin SA, Ramesh NR, Narasimham GV. (2015). Design and Fabrication of 10kV Potential Transformer. International Journal of Innovative Research in Science, Engineering and Technology (IJIRSET).
Chen J, Qin Y, Yan Y, Wu F, Li F. (2020). A Novel Calibration System for 35 kV Medium-voltage Capacitive Voltage Transformer Based on the Coulomb Field. Sensors (Basel).
Liu H, Li Z, Wang Y, Sun H, Lv B. (2015). A capacitive voltage sensor for 10 kV power systems. Sensors (Basel).
Dehdashti H, Ghavidel SP, Monfared M. (2017). A new dynamic ANN-based protection scheme for the 10KV distribution systems using S-transform. Electrical Engineering.
Yu X, Li Y, Zhao F. (2016). Energy-saving research on operational optimization of 10 kV distribution transformers. Journal of Modern Power Systems and Clean Energy.
Li Y, Chen L, Jin Z, Hao J, Feng X. (2019). A Comprehensive Power-Line Inspection System for 10 kV Overhead Power Lines Based on Unmanned Aerial Vehicles. Sensors (Basel).